Specialty Engineering

NERC Compliance, Dynamic Modeling, Substation Studies

We are the Power System Stability Group (PSSG) of Shermco. We provide advanced power system expertise to generator and substation owners so they can reliably interconnect to the Bulk Electric System. Our capabilities range from boots on the ground system testing and equipment configuration to specialized modeling system disturbances.

We differentiate ourselves by providing service where our clients’ concerns are central and by acting on opportunities where we know the client’s role in the power industry, in its technology, or both.

Shermco PSSG has performed hundreds of NERC Protection and Control (PRC) Standard assessments and Modeling, Data and Analysis (MOD) Standard generator tests and model validations for coal, gas, hydro, wind, and solar generation owners throughout the United States and Canada.

specialty enginering services

Dynamic Modeling

Positive Sequence Modeling (PSSE/PSLF)

In addition to dynamic models required for the above NERC standards, Shermco PSSG is experienced with specific additional requirements that sites registered in CAISO and ERCOT regions have to meet.

CAISO:

Complete data collectons for CAISO’s Generating and Interconnecting Facility data request and associated detailed reviews of dynamic models.

ERCOT:

Complete ERCOT reactive testing and ERCOT Model Ouality Tests (MOT), and Parameter Verifications.

specialty enginering services

EMT Modeling for Renewable Generation (PSCAD)

Many renewable generators are now required to provide Electromagnetic Transient (EMT) models for their sites so transmission planners can perform more detailed studies and grid performance assessments. Shermco PSSG works with the owner and equipment manufacturers to develop dynamic models that meet the requirements of entities such as ERCOT and CAISO.

EMT Model Validation

Shermco PSSG develops site EMT models utilizing PSCAD and validates the models against verified positive sequence models or other criteria as is required by CAISO, ISO NE, ERCOT, and others. We complete ERCOT Model Quality Tests (MQT), for sites in ERCOT’s region.

specialty enginering services

NERC Compliance Assessments

PRC-002

Disturbance Monitoring and Reporting Requirements

MOD-025

Verification and Data Reporting of Generator Real and Reactive Power

PRC-019

Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection

MOD-026

Verification of Models and Data for Generator Excitation Control System or Plant Volt/Var Control Functions

PRC-024

Generator Frequency and Voltage Protective Relay Settings

MOD-027

Verification of Models and Data for Turbine/Governor and Load Control or Active Power/Frequency Control Functions

PRC-025

Generator Relay Loadability

MOD-032

Data for Power System Modeling and Analysis

PRC-026

Relay Performance During Stable Power Swings

MOD-033

Steady-State and Dynamic System Model Validation

PRC-027

Coordination of Protection Systems for Performance During Faults

VAR-501

Power System Stabilizer (PSS)

FAC-008

Facility Ratings

Substation Studies

Power system studies determine system parameters during system disturbances. Performing these studies is essential to designing a reliable, safe site for generator and substation owners.

Insulation Coordination & Transient Overvoltage Study:
Perform insulation coordination studies and determine overvoltage levels due to switching events.

Transient Recovery Voltage Study:
Model overvoltage levels across circuit breakers during transition from conducting to non-conducting state to identify high voltage transients.

Harmonics Study:
Inverter based generation or non-linear loads can introduce harmonic distortion. Pre-and post-energization testing and modelling will quantify compliance with IEEE Standard 519.

Load Flow and Reactive Compensation Study:
Model feeders and substation to quantify real power load flow and reactive power compensation requirements to comply with interconnection agreement.

AC Short Circuit Study:
Model AC system down to the load side of feeder circuit breakers and assessment of short circuit current levels at the substation to compare fault currents to withstand rating of equipment identifying over-dutied equipment.

AC and DC Arc Flash Study:
Model AC system down to the load side of feeder circuit breakers and the DC system to evaluate Arc Thermal Performance Value in calories/cm2 for appropriate selection of Personal Protective Equipment.

Grounding Study:
Model equipment within the substation fence to provide a grounding design balancing the copper ground grid and insulating surface materials while maintaining step and touch potentials per IEEE-80.

Protective Device Coordination:
Using the fault currents calculated in the short circuit study, recommendations will be made for protection settings to coordinate with site and transmission line protection.

For more information on our Specialty Engineering services call us directly at (360) 413-9800 or reach out and fill out our quick informational form and let us know how SHERMCO can help you.

“If it’s in the Electrical Power System, SHERMCO does it!”

shermco industries block logo

Shermco
2425 East Pioneer Dr.
Irving, Texas 75061
Phone: 972.793.5523
Toll-Free: 888.SHERMCO
Fax: 972.793.5542

ONE LINE. ONE COMPANY.

©2024 Shermco
Privacy Policy | Site Map

shermco industries block logo
 
2425 East Pioneer Dr.
Irving, Texas 75061
Phone: 972.793.5523
Toll-Free: 888.SHERMCO
Fax: 972.793.5542
 

ONE LINE. ONE COMPANY.

©2023 Shermco
Privacy Policy | Site Map

shermco awea logo