Low to Medium Voltage Circuit Breaker Maintenance & Testing

$1,420.00

Many industrial customers choose to perform general testing and maintenance on incoming utility substations and downstream substations within the plant perimeters. This class provides the information and hands-on training to test and maintain most of the major components of the substation except for the main transformer and protective relays.

If you have several employees you would like to take this course, please reach out to us and we will contact you about a purchase order for your team.

*Please enter first and last name of one person per input

Description

Course Description: Many industrial customers choose to perform general testing and maintenance on incoming utility substations and downstream substations within the plant perimeters. This class provides the information and hands-on training to test and maintain most of the major components of the substation except for the main transformer and protective relays.

Prerequisites: Basic electrical training, some field experience and basic knowledge of switchgear.

Course Learning Objective:

  • Theory, construction, and operation of common types of medium voltage metal-enclosed switchgear and circuit breakers, including air-magnetic and vacuum.
  • How to interpret ratings and nameplate data and identify breaker ratings and vacuum
  • Understand how medium-voltage circuit breakers operate, and know the primary causes of failure.
  • Safety requirements when operating, racking, testing or maintaining circuit breakers
  • Required testing and maintenance of medium-voltage metal enclosed circuit breakers and switchgear in accordance with ANSI/NETA MTS.
  • Tests commonly performed on circuit breakers and their associated switchgear
  • How to maintain batteries in accordance with ANSI/NETA MTS
  • Ground testing theory and interpreting test results in accordance with ANSI/ NETA MTS

Hands-on Lab Session:

  • Racking circuit breakers
  • Perform and evaluate common circuit breaker electrical tests including insulation resistance, DC overpotential, contact resistance, insulation power factor and timing utilizing equipment from a variety of manufacturers.
  • Perform routine maintenance on medium-voltage air and vacuum circuit breakers
  • Perform clamp-on ground test and interpret the results
  • Test and evaluate battery systems.
shermco industries block logo

Shermco
2425 East Pioneer Dr.
Irving, Texas 75061
Phone: 972.793.5523
Toll-Free: 888.SHERMCO
Fax: 972.793.5542

ONE LINE. ONE COMPANY.

©2024 Shermco
Privacy Policy | Site Map

shermco industries block logo
 
2425 East Pioneer Dr.
Irving, Texas 75061
Phone: 972.793.5523
Toll-Free: 888.SHERMCO
Fax: 972.793.5542
 

ONE LINE. ONE COMPANY.

©2023 Shermco
Privacy Policy | Site Map

shermco awea logo